✒ Single Component Epoxy - No mixing A and B
✒ No induction time or pot life constraints
✒ Excellent stain resistance and stain removal
✒ Most Commercial cleaning agents will not damage paint film. MPC will withstand repeated cleaning.
✒ Excellent adhesion to a variety of substrates
✒ Good block resistance
✒ Soap and water clean-up
✒ Low odor, low VOC, meets OTC regulations
✒ Non-yellowing
Surface Preparation
GENERAL: Clean surfaces thoroughly to remove dirt, grease, oil, powdering plaster, glue size or paste and other surface contaminants that impair adhesion. Remove rust/scale from ferrous metal. Some galvanized metal may require Galvaprep pretreatment.
DRYWALL and PLASTER: Plaster must cure at least 30 days. Check drywall for excessive porosity. Some drywall may require a test application to determine the best sealer. Avoid abrading face paper when smoothing joint compound.
CONCRETE, CONCRETE BLOCK (CMU): Allow to cure at least 30 days. Remove loose or excess mortar, efflorescence, laitance and concrete form release or curing compounds that impair adhesion.
WOOD: Sand with the grain to a smooth surface. Spackle, sand and prime cracks and nail holes.
PREVIOUSLY PAINTED SURFACES: Clean and prepare as indicated above. Remove loose, peeling paint, chalk, rust, mildew, or other contaminants. Abrade smooth, glossy surfaces. Apply test patch(es) to confirm adhesion.

Application
Apply by brush, roller or airless spray in an even,
uniform manner making sure recesses and edges are
thoroughly coated.
Brush: High Quality Nylon/Polyester; any width
Roller: High Quality 3/8" or 1/2" nap woven cover
Spray Instructions
Airless Spray: Spray tip range: .021-.025. Best tip: #423
Airless Hose: 1/4" I.D. nylon lined. Filter: 60 - 100 mesh.
Pump: 3/4 GPM or higher.
Recommended Spread Rate
Approximately 280 - 370 sq. ft. per gallon. Rough or
porous surfaces require more paint.
Technical Data
Theoretical Coverage 620
(sq. ft. per gal. per dry mil)
Recommended DFT per coat 1.5-2.0 mils
Gloss 60o - 45 +/- 5
Wt/Gallon 10.86 ± 0.25 lbs.
Viscosity 92 ± 10 K.U.
Solids by Wt. 56 ± 2%
by Vol. 42 ± 2%
VOC as supplied 1.2 Lbs/gal - 150 gms/L
OTC Compliant
Flash Point (SETA) None
Color Quest P, M
Packaging Gallon, Five Gallon
Values are reported for white paint and will vary
depending on color. These values do not constitute
specifications.
Mixing/Stirring
Stir thoroughly with a spiral up and down motion at
intervals.
Clean Up
Clean tools and spray equipment immediately with a warm detergent solution and rinse thoroughly with clean water. Flush spray equipment with Paint Thinner to prevent rusting.
Drying Time
70°F and 50% Relative Humidity
To Touch: 1/2 - 1 hour To Recoat: 2 - 4 hours
40°F
To Touch: 4 hours To Recoat: 24 - 48 hours
Special Information
■Do not apply unless surface is at least 5°F above dew point, if condensation is present, or if air or surface temperature is below 40°F. Keep paint from freezing.
■Not recommended for immersion service, areas subject to constant high moisture levels or below grade application that may be subject to hydrostatic or water vapor pressure. Always confirm that surface is dry and not subject to such pressure.
■For severe chemical environments, contact Technical Department for specific recommendations.
■Read label warnings and precautions. Refer to MSDS for additional information.